home *** CD-ROM | disk | FTP | other *** search
-
- InterFlex Systems Design -- Superior Software for AEA and Kantronics TNCs
-
- << Welcome to PkGOLD and KaGOLD >>
-
- This functional demo program can be used several times. You can try
- multiple connects, Shell to DOS, Cut/Paste, and do many experiments
- with the program. The program will run for 30 minutes at a time, which
- is plenty of time to work through each of the following suggested
- exercises.
-
- SOUND DEMO
-
- The program starts by introducing you to the "Sound Demo" which makes
- HF "sounds" on your PC speaker, and explains what you are hearing.
- To skip the sound demo, answer "N" (no) to the first question. You
- will be given a chance to run the "live" demo after that.
-
- Things to Try
-
- Get the program going: PKDEMO or KADEMO (depending on which you have).
-
- Go through the Sound Demo, or Quit the Sound Demo to enter the Live Demo.
-
- Enter the right COM port and Baud rate. Then your callsign and name.
- You'll do this each time you run the program, the release edition saves
- this (and other settings) to disk and "comes up" much faster.
-
- The program will establish a link to your TNC. It may take a minute
- or so the first time you run the program, but once you've got things
- working, the program "comes up" very quickly.
-
- LESSON #1: Single Connect.
-
- Push [F1] for the Help Index. Use the Cursor or the first few letters
- of a help topic to "pick" the topic. Cross-reference items are highlighted
- by the cursor. To backup from a cross-reference item, use [Alt-F1].
-
- Read about Packet Mode, Packet Operating, Packet Parameters if you wish.
- Now let's do a single connect:
-
- 1. Type in just a callsign, e.g. WA4EGT or type in a path, such
- as WA4EGT or WA4EGT VIA DANAPT if you need to digipeat.
-
- Note: If you don't know who you can connect to, use the
- Mheard function, [Alt-F2]. Notice that when you depress the
- [Alt] key, the "keyline" below changes to show you what each
- key does. [Alt-F2] is shown as MHEARD.
-
- 2. Hit the [F7] key (connect key) when you've typed in a callsign.
- Don't type C CALLSIGN, just CALLSIGN then [F7].
-
- 3. After connecting, use [Alt-F7] to disconnect. Choose NORMAL
- disconnect. Notice that if frames are still pending, the
- disconnect is suspended until the frames are sent and
- acknowledged.
-
- If there is still time in the countdown sequence, hit [Alt-F7]
- again, and select to "cancel the disconnect" request. Then
- you will have to do step #3 again to initiate another disconnect
- request.
-
- 4. Go to the NETWORK VIEW screen using [F2] if you are not there
- already.
-
- 5. Go to the PREVIOUS SESSIONS screen using [F3]. Notice that
- the text of your previous session is there.
-
- 6. Return to the connected sessions using the [F4] key.
-
-
- LESSON #2: Multiple Connect
-
- 1. Type in a callsign or path (callsign VIA ...) and hit [F7].
-
- 2. Do step 1 at least once more, so that you have two (or more)
- sessions going. Don't worry about being on a session screen when
- you start another session. [F7] creates session windows on the fly
- (unlike other programs with fixed parameters).
-
- 3. Switch between sessions using the [F4] "NEXT" key.
-
- 4. Switch to the NETWORK VIEW screen using the [F2] key. Notice
- the full-screen.
-
- 5. See a list of stations to which you are connected by depressing
- the Ctrl key (by itself).
-
- 6. Go to each session using the [F4] key. Enter the operator's name
- using the [Alt-n] key sequence. Do this for each session. Names
- and QTH data is saved in a log file in the release version.
-
- 7. Go back to the NETWORK VIEW screen using [F2].
-
- 8. If text "comes in" from a session, and you are on another session
- screen, or the Previous Sessions or Network View screen, you will
- see a message "F4: <callsign>" in the bottom of the banner outline.
- Push [F4] "next" to go to that session immediately.
-
- 9. Go to each session using the [F4] key, and start typing a line
- but do not hit the [Enter] key to send it quite yet. Switch
- to each session and put in a partial line. Notice that each
- session has it's own "text entry/command entry" line. You can
- move the cursor using the "arrow" keys, overwrite or insert
- text. The program saves the cursor "state" for each session
- as you switch from session to session.
-
- 10. Initiate a disconnect on each session. When all are disconnected,
- go to the previous sessions screen using [F3] and review the
- sessions.
-
-
- LESSON #3: NET/ROM Node
-
- 1. Identify a node, or several nodes that you use and can hit
- easily. Determine the node ALIAS. There are a number of
- advantages to using node ALIAS names, rather than callsigns,
- such as:
-
- a. You can establish multiple connects to the ALIAS that
- are not possible using the node callsign.
-
- b. When a routed node disappears from the nodelist, you
- will be informed with "invalid callsign" if aliases are
- used. If just the callsign is used, and the routed node has
- been dropped or disappeared, the node attempting the
- route will drop back to an ordinary connect attempt and
- eventually retry out. Any callsign used and not found
- in the nodelist is assumed to be a direct connect from
- the node, and not a routed connect. Using ALIASES assures
- that if the node has been dropped from the routes, you
- will be immediately informed.
-
- 2. Assume the node is called NRNDE. You want to connect to W1AW
- after connecting to NRNDE. Type:
-
- NRNDE|W1AW
-
- on the command/text entry line and hit [F7]. The program will
- establish a connect to NRNDE-n and then issue a connect to
- W1AW automatically.
-
- 3. Establish a few connects using the NRNDE node. You will notice
- a couple of things:
-
- a. Each connect goes to a different SSID of NRNDE. For example
- you might see NRNDE-10, and NRNDE-13 etc. The program
- assures that if you use the "or bar (|)" technology, that
- multiple connects to the are established automatically.
-
- b. The connect progress is shown to you on the session screen.
-
- c. As you make progress, you will notice the callsign in the
- status banner indicates the current connected station.
-
- 4. If you have a two hop connect, like NRNDE and then to SECNDE,
- you can type:
-
- NRNDE|SECNDE|W1AW [F7]
-
- The program will establish a connect to NRNDE-n, then request
- a connect to SECNDE, and finally ask for a connect to W1AW.
-
- Note: BPQ nodes may require using a "port" number in the
- connect request (except when specifying a routed node in its
- internal node list). If W1AW is on port 1 of a BPQ node in
- the example above, you would type:
-
- NRNDE|SECNDE|C 1 W1AW [F7]
-
- 5. If you need to Digipeat into the first node, and the digipeater
- is N6WIK, try:
-
- NRNDE VIA N6WIK|SECNDE|W1AW [F7]
-
-
- LESSON #4: Quick Connects
-
- 1. Using the connect paths from prior examples, you can now
- setup a few "quick connects" or "point and shoot" connects.
-
- Once in the program, hit [Alt-S] for setup. Then highlight
- QUICK CONNECTS, then choose ADD.
-
- 2. Enter the name of the remote station, hit [Enter], then
- type in the path. For example:
-
- Name: ARRL HdQrtrs
- Path: NRNDE VIA N6WIK|SECNDE|W1AW
-
- 3. Do this for each callsign. Some "paths" may simply be the callsign
- of a station that is nearby, and doesn't require any special
- digipeating or node usage.
-
- When done, use the [ESC] key to bring you back to the program
- window area.
-
- 4. Press the [F7] key with a blank entry on the command line. This
- causes the program to present you with a "pick list" of your
- quick connects. Highlight one, and hit [Enter] to start the
- connect process. Do this for all of the entries in your Quick-
- Connects list.
-
- 5. Note: For emergency use, when "Tactical" callsigns are contemplated,
- enter the tactical callsign under as the NAME, and the FCC call
- in the PATH. Also enter the Tactical callsign as the "NAME" of
- the station in your NAMES list (created by [Alt-n] or in the
- setup area under Names).
-
-
- LESSON #5: Changing Parameters
-
- 1. Enter a parameter name, such as MYALIAS and hit [F10], the
- command key. The program will display the contents of the
- parameter.
-
- 2. Type a parameter and a value, such as MYALIAS FIRESTN followed
- by [F10]. This will enter the parameter value.
-
- 3. Type DISPLAY [F10] to see a list of parameter groups. Highlight
- one and hit [ENTER]. You may now move the cursor to a parameter
- and alter it's value. Typing DISPLAY M [F10] jumps immediately
- to the Monitor parameters.
-
- 4. Hit [F10] by itself (no parameters on the command entry line).
- You will see (at a minimum) STARTUP and SHUTDOWN. These are
- the names of special parameter files with the extension .TNC.
- Highlight STARTUP, hit [Enter] and notice that all of the
- startup parameters are loaded into your TNC.
-
- 5. Use [Alt-S] to get to the setup menu. Select TNC files.
- Highlight STARTUP and hit [Enter]. This is a .TNC file. You
- can edit it (we suggest not editing it unless you know what
- you wish to change). Use [F1] help to display your options.
-
- 6. In the setup area, under TNC files, you will notice <new> and
- <current>. Selecting <new> allows you to create a parameter
- file with settings you may wish to try. Experiment.
-
- LESSON #6: Sending CQ
-
- 1. On the Network View screen, hit [Alt-U] to enter the CQ/UNPROTO
- mode. Now anything you type on the screen followed by the
- [Enter] key is sent out as "unproto" or unnumbered information
- frames.
-
- 2. Look at the value of your UNPROTO by typing UNPROTO [F10].
- If it is not CQ, then set unproto to CQ by typing:
-
- UNPROTO CQ [F10]
-
- 3. Each time you leave the Network View screen, the CQ/Unproto
- switch is turned off. This is done to avoid sending frames
- that are by accident. If you stay on the Network View screen,
- and are in the CQ mode, all text you type is sent out as
- [UI] frames. You might set your UNPROTO to CQ VIA (some call).
- Then you can see your CQ frames.
-
-
- LESSON #7: Changing Program Options
-
- 1. Use [Alt-S] to bring up the setup menu. Select Setup from
- the menu. Explore the various menu areas.
-
- 2. Look at the Alt-n messages. Notice that ?CALL and ?NAME are in one
- or more messages. These are "macros" that are filled in by the
- program with the current CALL and NAME of the connected station.
- ALT-N messages are only active when connected or in [Alt-U] mode.
-
- 3. Look through other settings. There are several.
-
- LESSON #8: Maildrop Access
-
- 1. Use [Alt-F8] to access your maildrop.
-
- 2. Use the L)list, R)ead, K)ill etc. commands.
- Leave the maildrop with "B" for Bye.
-
- binary file transfer, conferencing etc.
-
- LESSON #9: For Multimode TNC (PK232, KAM) owners
-
- 1. Try the other modes. Use the enclosed "TNC" files if you
- wish. Hit [F10] (with no parameters on the command line)
- and highlight some mode, then hit ENTER.
-
- 2. Or change modes by simply typing the mode name then [F10].
-
- 3. The [ESC] key is the transmit key down and up key. In non-packet
- modes, start typing. When you want to key down and begin
- transmitting hit the ESC key. Keep typing away. When you've
- finished typing what and want your system to unkey after sending
- the text, hit ESC again. Your text will continue being transmitted
- until the text is sent, at which time it will unkey.
-
- To leave ARQ AMTOR, just type AMTOR [F10] or [Ctrl-F4]. To switch
- modes, type in the mode name then [F10], or use the TNC files for
- that mode by hitting [F10] and selecting a mode.tnc file.
-
- 4. AMTOR ARQ: Put the other station's SELCAL on the text entry line
- (e.g. WEGT) and push the [F7] or "connect" key. The TNC will begin
- Phasing in ARQ.
-
- To end an ARQ session use [Alt-F7] and select a "disconnect" mode.
-
- 5. FEC: On the PK-232, get into AMTOR mode. On the KAM, use [FEC] mode.
- Type in text, when you're ready to transmit FEC, just hit [ESC].
-
- 6. BAUDOT: Type BAUDOT [F10]. Set the shift and baud rate.
-
- LESSON #10: Why use a version of our GOLD software?
-
- We believe that our PkGOLD and KaGOLD software is the best available.
- We invite you to compare our products to ANY other program, including
- "new" program from the hardware companies.
-
- We were the first to offer binary file transfers, first to support the new
- Maildrop features in the AEA TNCs, first to have software for the dsp-2232,
- and first to offer conference mode, YAPP transfers, auto-recognition and
- exchange of data, and more.
-
- LAST LESSON: Ordering PkGOLD or KaGOLD
-
- 1. Get your VISA or MASTERCARD in front of you.
-
- 2. Call (714) 496-6639 and ask for a copy of the latest software
- for your TNC
-
- or
-
- 3. Send us a check, money order, or your VISA or MasterCard
- number to:
-
- InterFlex Systems Design Corp.
- Post Office Box 6418
- Laguna Niguel, CA 92607-6418
-
- Be sure to include your name, address, and callsign.
- VISA or MasterCard orders, please include a telephone
- number to call if any problems arise.
-
- Note: Price: $79.95 + $5 shipping. CA residents add 7.75%.
- Subject to change. Indicate whether you want PkGOLD Enhanced
- or KaGOLD DualPort. Or buy both for $129.95 plus shipping and
- sales tax (if in California).
-
-
- Good luck. We appreciate your business, and look forward to providing
- you the best software available.